首页文章Tenax-TA采样管6*150,60-80目,1/4*3.5英寸,6*90,不锈钢thc手机「Tenax-TA采样管6*150,60-80目,1/4*3.5英寸,6*90,不锈钢」

Tenax-TA采样管6*150,60-80目,1/4*3.5英寸,6*90,不锈钢thc手机「Tenax-TA采样管6*150,60-80目,1/4*3.5英寸,6*90,不锈钢」

时间2025-01-17 03:06:44发布yu分类文章浏览129
导读:Tenax -TA吸附采样管规格:200mg数量:尺寸:6mm*150mm品牌:HaoHan应用:GB5032--2020民用建筑工程室内环境污染控制标准GB50325-2010_民用建筑工程室内环境污染控制规范_设计规范在用热解吸毛细管气相色谱法分析室内空气或者环境空气中的苯和TVOC时,普遍使用tenax采样管。tenax采样管是一种内填tenax吸附剂...


Tenax -TA吸附采样管

规格:200mg

数量:

尺寸:6mm*150mm

品牌HaoHan

应用:

GB5032--2020民用建筑工程室内环境污染控制标准

GB50325-2010_民用建筑工程室内环境污染控制规范_设计规范


在用热解吸毛细管气相色谱法分析室内空气或者环境空气中的苯和TVOC时,普遍使用tenax采样管。tenax采样管是一种内填tenax吸附剂的玻璃管或内壁光滑的不锈钢管,采样前必须对采样管和吸附剂进行活化处理,尽可能降低采样管空白。GB/T18883-2002中要求“使干扰减到小”;GB50325-2010中要求“使用前应通氮气加热活化,活化温度应高于热解吸温度,活化时间不少于30min,活化无杂质峰”;DBJ01-91-2004附录E中明确要求“新tenax管使用前要活化16h,再次使用的,要活化到色谱图中干扰峰不大于样品峰面积的10%以上”。针对上述要求,现有技术中通常采用活化仪或老化仪对采样管活化处理,其基本原理都是在300℃~330℃的高温下使采样管中的残留物气化,再用一定量的惰性气流(0.1L/min以上氮气或氦气)将残留物吹扫出去,从而降低采样管空白。























Tenax-TA adsorption sampling tube


Specification: 200mg


quantity:


Size: 6mm*150mm


Brand: HaoHan


application:


GB5032--2020 Indoor Environmental Pollution Control Standard for Civil Construction Engineering


GB50325-2010_Code for indoor environmental pollution control of civil construction engineering_Design code



Tenax sampling tubes are commonly used in the ysis of benzene and TVOC in indoor or ambient air by thermal desorption capillary gas chromatography. The tenax sampling tube is a glass tube or stainless steel tube with a ooth inner wall filled with tenax adsorbent. Before sampling, the sampling tube and adsorbent must be activated to reduce the blank of the sampling tube as much as possible. GB/T18883-2002 requires "minimize interference"; GB50325-2010 requires "Before use, nitrogen should be heated for activation, the activation temperature should be higher than the thermal desorption temperature, the activation time should not be less than 30min, and the activation should be free of impurities. Peak"; Appendix E of DBJ01-91-2004 clearly requires that "the new tenax tube should be activated for 16 hours before use, and if it is used again, it should be activated until the interference peak in the chromatogram is not more than 10% of the sample peak area". In view of the above requirements, in the prior art, an activation instrument or an aging instrument is usually used to activate the sampling tube. Inert gas flow (nitrogen or helium above 0.1L/min) purges the residue, thereby reducing the blank of the sampling tube.

安宁版权声明:本网信息来自于互联网,目的在于传递更多信息,并不代表本网赞同其观点。其原创性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不作任何保证或承诺,并请自行核实相关内容。本站不承担此类作品侵权行为的直接责任及连带责任。如若本网有任何内容侵犯您的权益,请及时联系我们,本站将会在24小时内处理完毕,E-mail:xinmeigg88@163.com

展开全文READ MORE
采样管不锈钢英寸手机
手机怎么登陆路由器设置手机登录路由器「手机怎么登陆路由器设置」 详解手机版安卓应用宝的安装步骤应用宝下载手机版安卓「详解手机版安卓应用宝的安装步骤」